• Gossen Metrawatt

Characteristic Values

SECUTEST ST PRO 3P/SCHWEISS PAKET SECUTEST ST PRO SECUTEST SIII+H SECUTEST ST PRO BT COMFORT SECUTEST ST BASE COMFORTPAKET SECUTEST ST PRO PROFIPAKET SECUTEST ST PRO STARTERPAKET SECUTEST ST BASE
Item number M707B M708D M7010-V013 M707C M707A M708C M708B M708A
Product details page Details Details Details Details Details Details Details Details
Test sequences per VDE 0544-4 (welding equipment) x x x x x x x
Relocation management for site data (moving test objects) x x x x x
HTML report x x x x x x x
Test sequences per IC 62353 (medical devices) x x x x x x x x
Data transmission to PC via BT/USB x x x x x
Supply voltage 90Volt - 250Volt 90Volt - 250Volt 115Volt - 230Volt 90Volt - 250Volt 90Volt - 250Volt 90Volt - 250Volt 90Volt - 250Volt 90Volt - 250Volt
Test sequences for testing PRCDs x x x x x x x
Documentation software x x x x x x x x
Extension for testing and managing medical devices x x x x x x
Test sequences per IEC 60601 (medical devices)
Printer connection USB-A USB-A Other USB-A USB-A USB-A USB-A USB-A
Type of interface USB-B USB-B RS-232 USB-B USB-B USB-B USB-B USB-B
Indication Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic
Automatic test sequence x x x x x x x x
Limit value indication x x x x x x x x
Measured value memory x x x x x x x x
Deadlines management Optional Optional No Yes Optional Yes Optional Optional
Active testing x x x x x x x x
Passive testing x x x x x x x x
Protective ground resistance measuring range 0 - 30 0 - 30 0 - 30 0 - 30 0 - 30 0 - 30 0 - 30 0 - 30
Isolation resistance measuring range 0.01 - 300 0.01 - 300 0.05 - 300 0.01 - 300 0.01 - 300 0.01 - 300 0.01 - 300 0.01 - 300
Protective conductor current x x x x x x x x
Contact current x x x x x x x x
Differential current method x x x x x x x x
Direct method x x x x x x x x
Alternative method x x x x x x x x
Consumption current measurement x x x x x x x x
Power measuring x x x x x x x x
Voltage measurement x x x x x x x x
Connection for external measuring adapter x x x x x x x x
Testing of extension leads x x x x x x x x
Testing with 2 probes Yes Yes Yes Yes No Yes Yes No
Printer integrated
Suitable for use by an instructed person x x x x x x x x
Connection detection x x x x x x x x
Description of RFID x x x x x
DAkkS calibration certificate x x x x x x x x
Printing barcodes x x x x x x x
Import of data Yes Yes No Yes Optional Yes Yes Optional
Integrated rubber protection x x x x x x x
Measurement of time to trip of (P)RCDs x x x x x x x
Save measurement series x x x x x x x
Test current 10A x x x x x x
remote compatible Yes Yes Yes Yes Optional Yes Yes Optional
Safety class detection x x x x x x x x
Management of location data Optional Optional No Yes Optional Yes Optional Optional
Programmable test sequences Yes Yes No Yes Optional Yes Yes Optional
Frequency of supply voltage 50Hertz - 400Hertz 50Hertz - 400Hertz 50Hertz - 60Hertz 50Hertz - 400Hertz 50Hertz - 400Hertz 50Hertz - 400Hertz 50Hertz - 400Hertz 50Hertz - 400Hertz
High-voltage test
CC000739 Yes Optional Yes Optional
CC115226
CC115227 No

Dialogue, Information and Actions: