SECUTEST ST PRO | SECUTEST ST BASE | SECUTEST ST PRO BT COMFORT | SECUTEST SIII+H | SECUTEST SIII+ | 3P/SCHWEISS PAKET SECUTEST ST PRO | COMFORTPAKET SECUTEST ST PRO | PROFIPAKET SECUTEST ST PRO | STARTERPAKET SECUTEST ST BASE | |
---|---|---|---|---|---|---|---|---|---|
Item number | M707B | M707A | M707C | M7010-V013 | M7010 | M708D | M708C | M708B | M708A |
Product details page | Details | Details | Details | Details | Details | Details | Details | Details | Details |
Test sequences per VDE 0544-4 (welding equipment) | x | x | x | x | x | x | x | ||
Relocation management for site data (moving test objects) | x | x | x | x | x | x | |||
HTML report | x | x | x | x | x | x | x | ||
Test sequences per IC 62353 (medical devices) | x | x | x | x | x | x | x | x | x |
Data transmission to PC via BT/USB | x | x | x | x | x | ||||
Supply voltage | 90Volt - 250Volt | 90Volt - 250Volt | 90Volt - 250Volt | 115Volt - 230Volt | 115Volt - 230Volt | 90Volt - 250Volt | 90Volt - 250Volt | 90Volt - 250Volt | 90Volt - 250Volt |
Test sequences for testing PRCDs | x | x | x | x | x | x | x | ||
Documentation software | x | x | x | x | x | x | x | x | x |
Extension for testing and managing medical devices | x | x | x | x | x | x | x | ||
Test sequences per IEC 60601 (medical devices) | |||||||||
Printer connection | USB-A | USB-A | USB-A | Other | Other | USB-A | USB-A | USB-A | USB-A |
Type of interface | USB-B | USB-B | USB-B | RS-232 | RS-232 | USB-B | USB-B | USB-B | USB-B |
Indication | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic |
Automatic test sequence | x | x | x | x | x | x | x | x | x |
Limit value indication | x | x | x | x | x | x | x | x | x |
Measured value memory | x | x | x | x | x | x | x | x | x |
Deadlines management | Optional | Optional | Yes | No | No | Optional | Yes | Optional | Yes |
Active testing | x | x | x | x | x | x | x | x | x |
Passive testing | x | x | x | x | x | x | x | x | x |
Protective ground resistance measuring range | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 | 0 - 30 |
Isolation resistance measuring range | 0.01 - 300 | 0.01 - 300 | 0.01 - 300 | 0.05 - 300 | 0.05 - 300 | 0.01 - 300 | 0.01 - 300 | 0.01 - 300 | 0.01 - 300 |
Protective conductor current | x | x | x | x | x | x | x | x | x |
Contact current | x | x | x | x | x | x | x | x | x |
Differential current method | x | x | x | x | x | x | x | x | x |
Direct method | x | x | x | x | x | x | x | x | x |
Alternative method | x | x | x | x | x | x | x | x | x |
Consumption current measurement | x | x | x | x | x | x | x | x | x |
Power measuring | x | x | x | x | x | x | x | x | x |
Voltage measurement | x | x | x | x | x | x | x | x | x |
Connection for external measuring adapter | x | x | x | x | x | x | x | x | x |
Testing of extension leads | x | x | x | x | x | x | x | x | x |
Testing with 2 probes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Printer integrated | |||||||||
Suitable for use by an instructed person | x | x | x | x | x | x | x | x | x |
Connection detection | x | x | x | x | x | x | x | x | x |
Description of RFID | x | x | x | x | x | ||||
DAkkS calibration certificate | x | x | x | x | x | x | x | x | x |
Printing barcodes | x | x | x | x | x | x | x | ||
Import of data | Yes | Optional | Yes | No | No | Yes | Yes | Yes | Yes |
Integrated rubber protection | x | x | x | x | x | x | x | ||
Measurement of time to trip of (P)RCDs | x | x | x | x | x | x | x | ||
Save measurement series | x | x | x | x | x | x | x | ||
Test current 10A | x | x | x | x | x | x | x | x | |
remote compatible | Yes | Optional | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Safety class detection | x | x | x | x | x | x | x | x | x |
Management of location data | Optional | Optional | Yes | No | No | Optional | Yes | Optional | Yes |
Programmable test sequences | Yes | Optional | Yes | No | No | Yes | Yes | Yes | Yes |
Frequency of supply voltage | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 60Hertz | 50Hertz - 60Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz |
CC000739 | Yes | No | No | Yes | Yes | ||||
High-voltage test | 500Volt - 6000Volt | ||||||||
CC115226 | Optional | ||||||||
CC115227 | Optional |